{"id":22654,"date":"2024-04-15T15:16:37","date_gmt":"2024-04-15T13:16:37","guid":{"rendered":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/"},"modified":"2024-04-15T15:16:37","modified_gmt":"2024-04-15T13:16:37","slug":"vascular-access-button-for-mice-1-channel","status":"publish","type":"product","link":"https:\/\/2biol.com\/en\/prodotti\/vascular-access-button-for-mice-1-channel\/","title":{"rendered":"Vascular Access Button\u2122 for Mice &#8211; 1 channel"},"content":{"rendered":"<ul>\n<li>With a syringe equipped with a PNP3M injector or extension set, the miniaturized PinPort\u2122 built into the button can be accessed.<\/li>\n<li>With the VABMG tool, it is possible to hold the button and mouse without hemostats, taking advantage of magnets.<\/li>\n<li>A VABM1T and a 25-g swivel can be magnetically attached for continuous access.<\/li>\n<li><span style=\"color: #000000;\">Use one of the five colored aluminum VABM1C-5 caps to protect access.<\/span><\/li>\n<li><span style=\"color: #000000;\">The closed system enables aseptic and positive pressure technique that can improve patency by 5 times compared with standard externalized catheters<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The VAB\u2122 for mice is a transcutaneous port that provides rapid, aseptic access to a catheterized vessel with a syringe for intermittent access or with a ligature for continuous access. Applications include infusion, blood draw, and intravenous self-administration. There is a choice of three different types of discs that hold the button in place under the skin: <\/p>\n<ul>\n<li>14 mm polyester felt (VABM1B)-this is the standard configuration; the fabric will grow into the felt over time, securing it in place.<\/li>\n<li>10 mm polyester felt (VABM1VB) &#8211; smaller felt for smaller etching or smaller mice.<\/li>\n<li>14 mm silicone mesh (VABM1BSM) &#8211; preferred by Jackson Laboratory with its wide range of strains, some of which do not tolerate felt.<\/li>\n<\/ul>\n<p>The catheter connectors are subcutaneous, under the felt:<\/p>\n<ul>\n<li>25ga (standard) &#8211; for 2Fr polyurethane, including jugular vein and carotid artery catheters<\/li>\n<li>22ga &#8211; for polyurethane 3Fr<\/li>\n<\/ul>\n","protected":false},"featured_media":19015,"template":"","meta":[],"product_cat":[2697],"product_tag":[],"class_list":{"0":"post-22654","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-catheters-en","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Vascular Access Button\u2122 for Mice - 1 channel - 2B<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vascular Access Button\u2122 for Mice - 1 channel - 2B\" \/>\n<meta property=\"og:description\" content=\"The VAB\u2122 for mice is a transcutaneous port that provides rapid, aseptic access to a catheterized vessel with a syringe for intermittent access or with a ligature for continuous access. Applications include infusion, blood draw, and intravenous self-administration. There is a choice of three different types of discs that hold the button in place under the skin:    14 mm polyester felt (VABM1B)-this is the standard configuration; the fabric will grow into the felt over time, securing it in place.  10 mm polyester felt (VABM1VB) - smaller felt for smaller etching or smaller mice.  14 mm silicone mesh (VABM1BSM) - preferred by Jackson Laboratory with its wide range of strains, some of which do not tolerate felt. The catheter connectors are subcutaneous, under the felt:  25ga (standard) - for 2Fr polyurethane, including jugular vein and carotid artery catheters  22ga - for polyurethane 3Fr\" \/>\n<meta property=\"og:url\" content=\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/\" \/>\n<meta property=\"og:site_name\" content=\"2B\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/\",\"url\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/\",\"name\":\"Vascular Access Button\u2122 for Mice - 1 channel - 2B\",\"isPartOf\":{\"@id\":\"https:\/\/2biol.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg\",\"datePublished\":\"2024-04-15T13:16:37+00:00\",\"dateModified\":\"2024-04-15T13:16:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage\",\"url\":\"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg\",\"contentUrl\":\"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg\",\"width\":1000,\"height\":1333},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/2biol.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/2biol.com\/prodotti\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Vascular Access Button\u2122 for Mice &#8211; 1 channel\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/2biol.com\/#website\",\"url\":\"https:\/\/2biol.com\/\",\"name\":\"2Biological Instruments\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/2biol.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/2biol.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/2biol.com\/#organization\",\"name\":\"2Biological Instruments\",\"url\":\"https:\/\/2biol.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/2biol.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/2biol.com\/wp-content\/uploads\/2024\/01\/LOGO-2B-COMPLETO-vett.png\",\"contentUrl\":\"https:\/\/2biol.com\/wp-content\/uploads\/2024\/01\/LOGO-2B-COMPLETO-vett.png\",\"width\":700,\"height\":246,\"caption\":\"2Biological Instruments\"},\"image\":{\"@id\":\"https:\/\/2biol.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Vascular Access Button\u2122 for Mice - 1 channel - 2B","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/","og_locale":"en_US","og_type":"article","og_title":"Vascular Access Button\u2122 for Mice - 1 channel - 2B","og_description":"The VAB\u2122 for mice is a transcutaneous port that provides rapid, aseptic access to a catheterized vessel with a syringe for intermittent access or with a ligature for continuous access. Applications include infusion, blood draw, and intravenous self-administration. There is a choice of three different types of discs that hold the button in place under the skin:    14 mm polyester felt (VABM1B)-this is the standard configuration; the fabric will grow into the felt over time, securing it in place.  10 mm polyester felt (VABM1VB) - smaller felt for smaller etching or smaller mice.  14 mm silicone mesh (VABM1BSM) - preferred by Jackson Laboratory with its wide range of strains, some of which do not tolerate felt. The catheter connectors are subcutaneous, under the felt:  25ga (standard) - for 2Fr polyurethane, including jugular vein and carotid artery catheters  22ga - for polyurethane 3Fr","og_url":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/","og_site_name":"2B","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/","url":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/","name":"Vascular Access Button\u2122 for Mice - 1 channel - 2B","isPartOf":{"@id":"https:\/\/2biol.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage"},"image":{"@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage"},"thumbnailUrl":"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg","datePublished":"2024-04-15T13:16:37+00:00","dateModified":"2024-04-15T13:16:37+00:00","breadcrumb":{"@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#primaryimage","url":"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg","contentUrl":"https:\/\/2biol.com\/wp-content\/uploads\/2024\/04\/INSTECH-VAB-mice-1ch-1.jpg","width":1000,"height":1333},{"@type":"BreadcrumbList","@id":"https:\/\/2biol.com\/prodotti\/vascular-access-button-for-mice-1-channel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/2biol.com\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/2biol.com\/prodotti\/"},{"@type":"ListItem","position":3,"name":"Vascular Access Button\u2122 for Mice &#8211; 1 channel"}]},{"@type":"WebSite","@id":"https:\/\/2biol.com\/#website","url":"https:\/\/2biol.com\/","name":"2Biological Instruments","description":"","publisher":{"@id":"https:\/\/2biol.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/2biol.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/2biol.com\/#organization","name":"2Biological Instruments","url":"https:\/\/2biol.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/2biol.com\/#\/schema\/logo\/image\/","url":"https:\/\/2biol.com\/wp-content\/uploads\/2024\/01\/LOGO-2B-COMPLETO-vett.png","contentUrl":"https:\/\/2biol.com\/wp-content\/uploads\/2024\/01\/LOGO-2B-COMPLETO-vett.png","width":700,"height":246,"caption":"2Biological Instruments"},"image":{"@id":"https:\/\/2biol.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/product\/22654","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/product\/22654\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/media\/19015"}],"wp:attachment":[{"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/media?parent=22654"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/product_cat?post=22654"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/2biol.com\/en\/wp-json\/wp\/v2\/product_tag?post=22654"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}